SHORT COMMUNICATION
Year : 2011 | Volume
: 1 | Issue : 2 | Page : 72--74
Extrusion of Gore-tex implant after medialization thyroplasty
Evren Erkul, Hakan Cincik, Ahmet Ural Department of Otolaryngology Head and Neck Surgery, Gulhane Military Medical Academy, Haydarpasa Training Hospital, Istanbul, Turkey
Correspondence Address:
Ahmet Ural GATA, Haydarpasa Egitim Hastanesi, KBB Klinigi, 34668 Kadikoy, Istanbul Turkey
Various materials such as autogenous cartilage, silicone, hydroxylapatite, Gore-tex (expanded polytetrafluoroethylene), and titanium have been used for medialization laryngoplasty. We report an extrusion of Gore-tex implant after 11 months of medialization laryngoplasty. We believe tha t thought Gore-tex is a safe and easy-to-use implant for medialization laryngoplasty, the possibility of extrusion after the operation must not be ignored.
How to cite this article:
Erkul E, Cincik H, Ural A. Extrusion of Gore-tex implant after medialization thyroplasty.J Laryngol Voice 2011;1:72-74
|
How to cite this URL:
Erkul E, Cincik H, Ural A. Extrusion of Gore-tex implant after medialization thyroplasty. J Laryngol Voice [serial online] 2011 [cited 2022 May 20 ];1:72-74
Available from: https://www.laryngologyandvoice.org/article.asp?issn=2230-9748;year=2011;volume=1;issue=2;spage=72;epage=74;aulast=Erkul;type=0 |
|
|